Whyte-Hall (Australia) Pty Limited - Equipment for hazardous and potentially explosive environments
Whyte-Hall
  
Login Click here to Join
Keyword Search:
Go

Wolf Fluorescent Leadlamp

LEADLAMPS


Wolf Fluorescent Leadlamp in use image
Ex Certified - Hexagon
CE 1180 Certified
  • ATEX Approved for zone 1 & 2 explosive gas and dust atmospheres
  • Fitted with plugs and sockets, linkable in series
  • Twin or quad lamp configuration
  • Compact & robust design
  • Wide voltage range 24V - 254V
  • Uses standard compact fluorescent lamps for ease of  maintenance
  • Control ballast incorporates 'End of Life' protection circuit
  • Integrated Unistrut compatible mounting points 
  • Emergency lamp variant available

 

product image jpeg

Wolf Fluorescent Leadlamp

Product Description

The Wolf ATEX Portable Fluorescent Leadlamp is CE marked to the 94/9/EC ATEX Equipment Directive, allowing use in Zone 1 (Cat 2) IIC potentially explosive gas, vapour, mist and dust atmospheres, where a T3/T4 temperature class permits.

Available with twin side by side forward facing, or quad back to back 18W, 36W or 55W energy efficient fluorescent lamp combinations in a wide range of voltages (24V – 254V) the luminaires are suitable for a multitude of applications where a temporary light is required for extended periods of time inside a potentially hazardous area. 

The Luminaires can be supplied with direct cable entries or fitted with ATEX plugs/sockets to allow the units to be instantly linked in series (plug and play), allowing for quick and easy installation over a large area.

Unistrut compatible mounting points located on the lamps provide a flexible installation solution allowing the luminaires to be quickly and easily fixed in position on pipes, scaffold or a ferrous backdrop with magnetic fixings.  A Wide range of Unistrut compatible products are available providing a quick, easy and low cost solution for mounting the lamps

Easy maintenance is a key feature of Wolf Portable Fluorescent Leadlamp range, re-lamping is simple and quick using standard compact fluorescent lamps readily available from electrical retailers, The operation takes no more than a few minutes and can be done by any competent electrical engineer.

Rugged construction, and compact design allow lights to be connected together in the explosive atmosphere while energised. A hanging/carrying strap is supplied as standard. Portable versions are supplied with an anti-static protective coating.

Compliant with the ATEX Equipment Directive and certified to the latest standards, including ‘End of Life’ protection circuit ballast for enhanced safety, in accordance with HSE safety notice 8/05.

An Emergency T4 version is available with T8 Lamp operating at 110V or 240V only.

A range of ATEX compliant transformers is available, rugged design and construction for use in or near hazardous locations. 

Technical Specification

Wolf Portable Leadlamp - LL-500
2 x 36W 180° or 4 x 36W 360° Worklight
Peak Luminous Intensity at 5m 138 lux
Peak Luminous Intensity at 2.5m 36 lux

 

Product Reference LL-500
Product Description ATEX Fluorescent Leadlamp
Code II 2 GD Ex emb II T3/T4 Ex tD A21 IP66/67/68 T100°C
II 2 GD Ex embd IIC T3/T4 Ex tD A21 IP66 T100°C (Linkable)
Apparatus Standards EN60079-0, EN60079-7, EN60079-18, EN61241-0, EN61241-1
Type of Protection "e" increased safety, "m" encapsulation, "d" flameproof
Area of Classification (Gases)   Zones 1 & 2, Gas Groups IIA, IIB, IIC
Temperature Class T3 on CFL Portable Units
T4
on 'T8' lamp Static Application Units
Area of Classification (Gases)  Zones 21 & 22
  Max Surface Temp (Dusts) 100°C
Ambient Temperature 2 x CFL Unit: (-20°C to +44°C)
4 x CFL Unit: (-20°C to +35°C)
2 x T8 Unit: (-20°C to +53°C)
2 x T8 Emergency Unit: (-15°C to +53°C)
Certificate SIRA08ATEX3098
Enclosure Polymer / Aluminium End Caps
Lens Polycarbonate with AntiStatic Coating
Beam Type Wide angle, White, Area Light High Output, High Efficiency, Low Glare
Light Source:   Type Standard 2G11 CFL Compact Fluorescent / T8 Fluorescent Lamps
Life Up to 10,000 hrs
Power
2x18W 4 x 18W 2 x 36W 4 x 36W 2 x 55/58W 4 x 55/58W
Typical Consumption
32W
64W 62W 124W 92W 184W
Output 2400lm 4800lm 5800lm 11600lm 9600lm 19200lm
Voltage 220-254V AC/DC
110-130V AC/DC  -
42 - 52V AC/DC -
-
24 - 28V AC/DC -
-
- -
Weight 2.7kg 4.1kg 4.1kg 5.5kg 5.0kg 6.4kg
Length 0.3m 0.62m 0.58m 0.82m 0.78m 0.94m
Ingress Protection IP66/67/68 (3M for 30 Minutes)

All products supplied with 4mm2 SY Cable and ATX plugs/sockets as standard.
All non-linkable lamps supplied with 10m of cable, all linkable lamps supplied with 5m of cable as standard.
All products supplied with fluorescent lamps fitted as standard.
Changes to the above specifications available on request.

Should you have any further questions please click here to email us.

 

Ó 2005 Whyte-Hall (Australia) Pty Limited

Back Email a Friend View Printable Version
eknowhow | The World's Best Websites
  Privacy Policy and Disclaimer